Excellent hmi touch screen wholesale provider: Inherent human weaknesses: people have inherent weaknesses such as forgetfulness, error-prone, inattentiveness and emotional instability. A well-designed human-machine interface should minimize the amount of user memory when operating and using, and should strive to avoid possible errors; The user’s knowledge and education: the user’s education level determines his knowledge and experience of the computer system. China is the world’s largest market in terms of HMI demand, but it is not the world’s highest market in terms of HMI product sales, which means that low-end HMI users occupy a large share in China. The rapid development of national brands in recent years, taking low prices and other strategies, is attacking the low-end market in a big way, and has occupied a dominant position in the low-end market in China, winning the recognition of the majority of users. International brands are also gradually developing their economic products to capture the share of the low-end market. As a result, the overall performance of domestic HMI manufacturers has shown rapid growth due to their steady presence in the low-end market. Find more information on hmi panel manufacturers.

Selecting the installation method: The installation mode of plc system is divided into centralized, remote i/o and distributed with multiple plc networking. Centralized hardware does not need to be set to drive remote i/o hardware, the system response is fast and cost is low; Remote I/O type is suitable for large systems, the system device distruibution range is very wide, remote i/o can be scattered installed near the field device, the connection is short, but need to add drivers and remote i/o power supply; The distrbuted network of multiple plc is suitable for the occasions where multiple devices are independently controlled and interconnected, and small plc can be selected, but communication module must be attaced.

Consistency principle: Including the consistency of color, operation area consistency, text consistency. That is, on the one hand, the interface color, shape and font are consistent with national, international or industry common standards. On the other hand, the interface color, shape and font are self-contained, and the color of different devices and their same design state should be consistent. Consistency in the aesthetic design of the interface details makes the operator feel comfortable when looking at the interface, so as not to distract his attention. Consistency also reduces errors for new operators, or for operators dealing with problems in emergency situations.

Wuxi Mochuan Drives Technology Co.,Ltd is one manufacturer and system solution company. To quickly match the high advantage competitive model through industry experience and solution to bring a high value market and a new growth point for our customers. We mainly provide  Hmi Panel, Hmi Touch Screen , Plc Controller and permanent magnet motor. To explore more equipment value for equipment manufacturers and end users, improve efficiency, reduce costs, optimize management, and promote equipment manufacturers’ service transformation. See extra information at https://www.mochuan-drives.com/.

Specific methods : First, the parameters of the touch screen. Check the parameter settings of the touch screen. Connect the PLC programming software to the PLC test to see what the PLC parameters are and whether the parameters set in the project are the same as those tested. There are several parameters that require special attention: 1. Communication port settings – be sure to confirm that the COM1 port or COM2 port of the PLC connected to the touch screen is clear;2. Device type – this is the most important. If the protocol is not selected correctly, nothing else needs to be said. 3. connection method – the connection between the PLC and the HMI operator interface, confirming whether it is RS485 or RS232C. 4. The touch panel interface parameter is the same as the PLC station number – it must be the same as the setting in the PLC. Next, if the parameters are set to confirm, troubleshoot the wiring.

Multiple color of shell and panel cutout for selecting, it is more flexible to match different project to improve the overall aesthetics and practical. Suggestions and recommendations to our customers through over a decade field experience industry and industry solution through software and hardware, if you work with us. If require the special technology, special function, special size, special parameter, special color, shape or special performance of ihm, welcome contact us for ODM. Mochuan hmi panel manufacturers will be very seriously and give timely feedback.

The regular China lcd human machine interface HMI touch screen is only to support 0°C to 50°C working envornment. HMI panel can not meet the application, the environment require the high or low temperature. It have to find the solution, such as to add one resistance or move the equipment in door or outdoor to make the temperature is suitabe its work needing. But face one question, it is not stable and very inconvenience. To solve this problem, to develop and design new type HMI touch panel, it is metal shell wide-temperature resistive HMI, supporting -20°C to 70°C. This type wide-temperature screen is very popular in Canada, Russia, United States…etc.

The Fourth Step: Communication Mode Preference is given to the HMI Panel itself with lower computer drive touch screen. Firstly, this is will be more convenient and simple in the definition of the subsequent project address and conversion, becuase if you choose Modbus compatible devices, it is necessary to convert the HMI touch screen monitoring address according to the rules of the definition of different lower computer(PLC) manufacturer, which not only greatly increase the workload of engineers and also easy to covert the wrong. Secondly, needing to draw up in advance, a communication program for the entire project. Do it need the ethernet to communicate with the upper computer, or need two rs485 to be maste or slave station communication, or through one rs485 and one rs232 communication to achieve.

Industrial grade fully enclosed embedded industrial hmi touch panel can perfectly cope with all kinds of harsh environment, but also can bring more convenient management services: Installation of embedded industrial hmi touch screen panel in the electrical room cabinet is more conducive to intelligent monitoring and management of the equipment in the electrical room. Through the touch screen monitoring display, you can monitor and detect the running temperature, power output, output power and other conditions of the electrical chassis cabinet in real time to ensure the stable and efficient operation of the electrical room.

Human-Computer Interaction (HCI): The science of designing, evaluating, and implementing interactive computing systems for use by people and the study of these phenomena. HCI and human-computer interface are two concepts that are closely related but not identical. The RelationShip Between Human Computer Interaction and HMI: Human-computer interaction is the interaction between a human and a machine, which is essentially the interaction between a human and a computer. Or from a broader perspective: HCI refers to the interaction between a human and a machine containing a computer.